Greenstar Camray Utility System 25/32 is an oil fired condensing boiler of market leading range from Worcester Greenstar Camray Utility System series boilers. An advance and highly efficient process helps to reduce utility bills by between 5% - 10%. Significantly it releases less carbon dioxide in the atmosphere – environment friendly.Greenstar Camray Utility System 25/32 converts 93% of its fuel into useful heat for domestic central heating and hot water. Greenstar Camray Utility System 25/32 is ideal for the house with two or more bathrooms.
Greenstar Camray Utility System 25/32 condensing boilers provide this energy-saving performance by recycling exhaust gases to extract and re-use latent heat. This highly efficient use of energy which also significantly reduces carbon dioxide in the atmosphere.
Pick up only NO DELIVERY - you must make arrangements to pick item up.
Key Features:
-
18kW, 25kW and 30kW output
-
SEDBUK(Seasonal Efficiency of Domestic Boilers in the UK) A Rated – more environmentally friendly
-
Smallest utility system compared to competition
-
Robust quality manufacture – excellence comes as standard
-
Oil isolation valve
-
Compatible with Greenskies solar water heating
-
5 year warranty - Subject to conditions
Specification:
| Title |
Value |
| Height (mm) |
855mm |
| Width (mm) |
370mm |
| Depth (mm) |
600mm |
| Weight |
118kg |
| SEDBUK Value/band |
94.2% Band A |
| Solar compatible |
Yes |
| Burner |
Riello RDB 2.2 |
| Minimum diameter flue CF |
130 |
| Minimum diameter flue RS |
80/125, 100/150 |
| Primary vent |
1¼ inch BSP |
| Primary cold feed |
3/4 inch BSP |
| Heating flow and return connections |
28mm |
| Condensate connection |
21.5 |
| Condensate trap |
Accessory kit supplied |
| Oil connection |
10 |
| Max. primary static head |
30 |
| Min. primary static head |
01 |
| Primary water content |
28 |
| NOx classification |
Class 3, 50mg/kWh |
| Available pump head 20°C |
4.1 mH2O |
| Exhaust flue gas mass flow |
51 |
| Control thermostat range |
55/81 |
| Power consumption |
265 |
| Ingress protection rating |
IP20 |
| Flue reset overheat thermostat (cut out) (°C) |
110 |
| Boiler manual reset overheat thermostat (cut out) |
105 |
| Boiler high limit thermostat (cut out) (°C) |
95 |
| Max. horizontal flue RS 80/125 (mm) |
4,000 |
| Max. vertical flue RS 80/125 (mm) |
8,000 |
| Maximum hearth temperature |
<100 |
| Power supply |
230V, 50Hz |