The Greenstar Camray Utility 18/25 (floor standing) is part of a market-leading range of energy-saving condensing oil-fired boilers from Worcester. The Worcester Greenstar Camray Utility 18/25 is designed to provide energy-efficient heating and hot water with very less effect on the environment.At least 93% of the oil consumed by a Greenstar Camray Utility condensing regular boiler is converted into heat for the heating and/or hot water system and they can cut heating and hot water bills by between 5-10%.
Greenstar condensing boilers deliver this energy-saving performance by recycling exhaust gases to extract and re-use latent heat.This highly efficient use of energy which also significantly reduces carbon dioxide in the atmosphere. This model is compatible with existing Greenstar Oilfit 80/125mm flue systems.
Pick up only NO DELIVERY - you must make arrangements to pick item up.
Key Features:
-
SEDBUK(Seasonal Efficiency of Domestic Boilers in the UK) A Rated – environmentally friendly
-
Robust quality manufacture – excellence comes as standard
-
Compatible with Greenskies solar water heating
-
18kW, 25kW and 30kW output
-
Oil isolation valve
-
5 year(subject to condition) warranty
Specification:
| Title |
Value |
| Height (mm) |
855mm |
| Width (mm) |
370mm |
| Depth (mm) |
600mm |
| Weight |
103kg |
| SEDBUK Value/band |
93.2% Band A |
| Solar compatible |
Yes |
| Burner |
Riello RDB 2.2 |
| Minimum diameter flue CF |
100 |
| Minimum diameter flue RS |
80/125 |
| Primary vent |
1 inch BSP |
| Primary cold feed |
3/4 inch BSP |
| Heating flow and return connections |
1 inch BSP, 22mm |
| Condensate connection |
21.5 |
| Condensate trap |
Accessory kit supplied |
| Oil connection |
10 |
| Max. primary static head |
30 |
| Min. primary static head |
1 |
| Primary water content |
23 |
| NOx classification |
Class 3, 50mg/kWh |
| Water side resistance 20°C |
52 |
| Exhaust flue gas mass flow |
40 |
| Control thermostat range |
55/81 |
| Power consumption |
160 |
| Ingress protection rating |
IP20 |
| Flue reset overheat thermostat (cut out) (°C) |
110 |
| Boiler manual reset overheat thermostat (cut out) |
105 |
| Boiler high limit thermostat (cut out) (°C) |
95 |
| Max. horizontal flue RS 80/125 (mm) |
4,000 |
| Max. vertical flue RS 80/125 (mm) |
8,000 |
| Maximum hearth temperature |
<100 |
| Power supply |
230V, 50Hz |