The Greenstar Camray External series is part of a market-leading range of energy-saving condensing oil-fired boilers from Worcester. Almost 93% of the oil consumed by a Greenstar Camray External 12-18 condensing regular boiler is converted into heat for the heating and/or hot water system and they can reduce heating and hot water bills by between 5-10% and leaves less impact on the atmosphere.This external boiler is suitable for the property type which doesn't have appropriate space to place boiler inside.
These condensing boilers use an innovative method of reusing the heat from exhaust gases as a secondary heating source to get such a high efficiency. The latent heat within exhausts from the boiler is extracted and recycled to contribute to the heating or hot water system which minimises energy lost in the procedure and parelally all these processes leave less carbon dioxide in the atmosphere.
Pick up only NO DELIVERY - you must make arrangements to pick item up
Key Features:
-
Built-in frost protection
-
SEDBUK(Seasonal Efficiency of Domestic Boilers in the UK) A Rated – environmentally friendly
-
18kW, 25kW and 30kW outputs
-
Ideal solution for saving internal property space
-
Compatible with Greenskies solar water heating
-
High quality insulated weatherproof cabinet – resistant to water, dust and the external elements
-
5 year warranty (Subject to condition)
Specification:
| Title |
Value |
| Height (mm) |
950mm |
| Width (mm) |
565mm |
| Depth (mm) |
780mm |
| Weight |
114kg |
| SEDBUK Value/band |
93.1% Band A |
| Solar compatible |
Yes |
| Burner |
Riello RDB 1 |
| Minimum diameter flue RS |
80/125 |
| Primary vent |
1 inch BSP |
| Primary cold feed |
3/4 inch BSP |
| Heating flow and return connections |
1 inch BSP, 22mm |
| Condensate connection |
21.5 |
| Condensate trap |
Accessory kit supplied |
| Oil connection |
10 |
| Max. primary static head |
30 |
| Min. primary static head |
1 |
| Primary water content |
23 |
| NOx classification |
Class 3, 80mg/kWh |
| Water side resistance 20°C |
26 |
| Exhaust flue gas mass flow |
29 |
| Control thermostat range |
55/81 |
| Power consumption |
150 |
| Ingress protection rating |
IP45 |
| Flue reset overheat thermostat (cut out) (°C) |
110 |
| Boiler manual reset overheat thermostat (cut out) |
105 |
| Boiler high limit thermostat (cut out) (°C) |
95 |
| Max. horizontal flue RS 80/125 (mm) |
175 |
| Maximum hearth temperature |
<100 |
| Power supply |
230V, 50Hz |