Worcester-Combi-Greenstar Heatslave 18-25

Open Arrow
Only £1769.95 (Inc.)
£1506.34(Exc.)
Normally available within 5-7 days
Part No.: 7716100098
Customer Rating :
Description
Review
Delivery info
Email a friend
Description

The Greenstar Heatslave 18/25 is part of a market-leading range of energy-saving condensing oil-fired boilers from Worcester combi series. At least 90% of the oil consumed by a Greenstar Heatslave condensing combi boiler is converted into heat for the heating and/or hot water system and help to cut heating and hot water bills by between 5-10%. The Greenstar Heatslave 18/25 is appropriate for a small to medium sized, 1 bathroom apartment, house or bungalow. The Greenstar Heatslave 18/25 is ideal for replacing an existing boiler located in a utility room, garage or kitchen.

Greenstar condensing boilers deliver this energy-saving performance by recycling exhaust gases to extract and re-use latent heat - a highly efficient use of energy which also significantly reduces carbon dioxide in the atmosphere.

Pick up only NO DELIVERY - you must make arrangements to pick item up.

Key Features:

  • SEDBUK A Rated ? environmentally friendly
  • Pre-heated thermal store ? instantly heated hot water
  • Optional fascia mounted programmer ? reduced wiring 18kW, 25kW and 32kW DHW (domestic hot water) and CH (central heating)
  • More than 90% efficient 
  • 5 year warranty (subject to condition)

Specification:

Title Value
Height (mm) 855mm
Width (mm) 520mm
Depth (mm) 600mm
Weight 177kg
SEDBUK Value/band 90.1% Band A
Solar compatible No
Minimum diameter flue CF 100mm
Minimum diameter flue RS 80/125mm
Mains cold water inlet 15mm
Domestic hot water outlet 22mm
Primary vent 3/4" inch BSP
Primary cold feed 1 inch BSP
Heating flow and return connections 22mm
Condensate connection 21.5mm polypropylene
Oil connection 10mm
Max. primary static head 30 metres
Maximum flow temperature 55/81°C
Min. primary static head 1 metre
Primary water content 69 litres
NOx classification Class 3, 70mg/kWh
Water side resistance 20°C 110 mbar
Exhaust flue gas mass flow 40kg/hr
Control thermostat range 5°C
Power consumption 240W
Ingress protection rating 20 IP
Flue reset overheat thermostat (cut out) (°C) 110°C
Boiler manual reset overheat thermostat (cut out) 105°C
Boiler high limit thermostat (cut out) (°C) 92%
Maximum hearth temperature 100°C
Maximum horizontal flue RS 4,000mm
Maximum vertical flue RS 6,000mm
Power supply 230 AC V 50Hz